Diatomite [EM Diatomite] 100% natural material, breathing plastering materials

Disadvantages - If a whole building is moved by earthquake or vibration of road, cracks may be occurred
Crack might be occurred as a one of general features of plaster wall, regardless diatomite.
There are several causes for it and we describe major ones.

(1) In case of the movement of the undercoat

Undercoat may move due to wide space between the plasterboards or studs. It is better that the pitch is 10cm at the least.
Also, few numbers of joints are better, so we recommend using 910mm x 2730mm plasterboard and put vertically, if possible. When you use 910mm x 1820mm plasterboard, you should insert undercoat materials horizontally without skipping the undercoat between each pitch, not to mention vertically.

(2) In case of the movement of a whole building by earthquake or vibration of road

Since PVC stretches little, it is hard to imagine that crack appears, even if the undercoat is moved slightly by earthquake, except for extraordinary occasions. However, in case of plaster walls (especially 100% natural materials), when a building is moved widely, it is unavoidable that some cracks are occurred. Thus, it is required to strengthen joints with a fiber tape to fix the undercoat as much as possible.
home

(3) In case of mix with wrong amount of water

When you mix the diatomite with wrong amount of water, it will cause crack of the surface. Even the expert painter, it is very important to measure the water for avoiding crack, especially for 100% natural diatomite.
Next, we will show you further special features of "EM Diatomite".